ISO 7000 - Ref-No 0034.svg[Quelltext bearbeiten]

  • ISO 7000 - Ref-No 0034A.svg
Function/description: To indicate temperature or function associated with temperature (for example, temperature indication, temperature monitoring points).
Additional information:
The unit of measurement, for example ""C°"", may be a dded to symbol.

IEC 60417 - Ref-No 5001A.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5001-1994.svg
Function/description: To identify a device related to the supply of equipment by means of a (primary or secondary) battery, for instance a battery test button, the location of the connector terminals, etc.
Additional information:
* To identify a battery check function, the use of symbol 5546 is recommended. * This symbol is not intended to be used to indicate polarity * Published in: Supplement M, 1994;First edition, 197

IEC 60417 - Ref-No 5003.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5003-1975.svg
Function/description: To identify an AC/DC-converter and, in case of plug-in devices, to identify the relevant receptacles.
Additional information:
* See also symbols 5186, 5194, 5284 and 5302 * Published in: Supplement B, 1975;First edition, 1973

IEC 60417 - Ref-No 5009.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5009Rev.svg
Function/description: [To identify the switch or switch position by means of which part of the equipment is switched on in order to bring it into the stand-by condition, and to identify the control to shift to or to indicate the state of low power consumption. Each of different states of power consumption may be indicated using a corresponding colour.]
Additional information:
* See also IEC 60417-5266 * 2014-07-18: 3C/1928/CD (2CD);2014-11-21: 3C/1951/CC;2014-11-28: 3C/1958/CDV;2015-03-13: 3C/2036/RVC * Published in: First edition, 1973
  • IEC 60417 - Ref-No 5009Rev2.svg
Function/description: [To identify the switch or switch position by means of which part of the equipment is switched on in order to bring it into the stand-by condition, and to identify the control to shift to or to indicate the state of low power consumption. Each of different states of power consumption may be indicated using a corresponding colour.]
Additional information:
* See also IEC 60417-5266 * First edition, 1973;Evaluated by C00448 and replaced by 5009Rev3 on 2015-05-09.
  • IEC 60417 - Ref-No 5009(2002-10-07).svg
Function/description: To identify the switch or switch position by means of which part of the equipment is switched on in order to bring it into the stand-by condition.
Additional information:
* See also symbol 5266 * Published in: First edition, 1973
  • IEC 60417 - Ref-No 5009(2015-03-14).svg
Function/description: [To identify the switch or switch position by means of which part of the equipment is switched on in order to bring it into the stand-by condition, and to identify the control to shift to or to indicate the state of low power consumption. Each of different states of power consumption may be indicated using a corresponding colour.]
Additional information:
* See also IEC 60417-5266 * [2014-07-18: 3C/1928/CD (2CD);2014-11-21: 3C/1951/CC;2014-11-28: 3C/1958/CDV;2015-03-13: 3C/2036/RVC;] * Published in: First edition, 1973

IEC 60417 - Ref-No 5015.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5015-1973.svg
Function/description: To identify the switch or control which operates the air impeller, e.g. a fan of a film or slide projector, a room fan.
Additional information:
Published in: First edition, 1973

IEC 60417 - Ref-No 5017.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5017-1985.svg
Function/description: To identify an earth (ground) terminal in cases where neither the symbol 5018 nor 5019 is explicitly required.
Additional information:
Published in: Supplement G, 1985;Supplement C, 1977

IEC 60417 - Ref-No 5018.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5018-1977.svg
Function/description: To identify a noiseless (clean) earth (ground) terminal, e.g. of a specially designed earthing (grounding) system to avoid causing malfunction of the equipment.
Additional information:
Published in: Supplement G, 1985;Supplement C, 1977

IEC 60417 - Ref-No 5019.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5019-1985.svg
Function/description: To identify any terminal which is intended for connection to an external conductor for protection against electric shock in case of a fault, or the terminal of a protective earth (ground) electrode.
Additional information:
Published in: Supplement G, 1985;Supplement C, 1977

IEC 60417 - Ref-No 5039.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5039-1973.svg
Function/description: To identify the aerial (antenna) terminals. This symbol should be used unless it is essential to specify the type of aerial (antenna).
Additional information:
Published in: First edition, 1973

IEC 60417 - Ref-No 5042.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5042-1973.svg
Function/description: To identify the frame aerial (loop antenna) terminals.
Additional information:
Published in: First edition, 1973

IEC 60417 - Ref-No 5044.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5044-1973.svg
Function/description: To identify the switch by which the circuit is connected that attenuates stronger local signals in order to avoid overloading of input circuits.
Additional information:
Published in: First edition, 1973

IEC 60417 - Ref-No 5047.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5047-1973.svg
Function/description: To identify the switch position in which the muting (squelch) circuit is switched on.
Additional information:
Published in: First edition, 1973

IEC 60417 - Ref-No 5049.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5049-1973.svg
Function/description: To identify the controls and terminals specifically meant for (mainly monochrome) video signals.
Additional information:
Published in: First edition, 1973

IEC 60417 - Ref-No 5104.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5104-1973.svg
Function/description: To identify the start button.
Additional information:
* See also symbols 5177 and 5639 * Published in: First edition, 1973

IEC 60417 - Ref-No 5110A.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5110-1973.svg
Function/description: To identify the control device by means of which an action is stopped.
Additional information:
* This means stopping only by partial electical disconnection. * See also symbol 5178 * Published in: First edition, 197

IEC 60417 - Ref-No 5111A.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5111-1973.svg
Function/description: To identify the control device by means of which the run (e.g. of a tape) is interrupted by means of a break mechanism and mechanical disconnection from the driving mechanism which continues to run.
Additional information:
Published in: First edition, 197

IEC 60417 - Ref-No 5124A.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5124A-2002.svg
Function/description: To identify the switch or switch position by means of which a slower than normal run (e.g. of tape) is started in the indicated direction.
Additional information:
* In the orientation shown, the symbol means ""slow run, forward"". If shown reversed, the symbol means ""slow run, backward * Published in: Supplement K, 1991;Supplement J, 1990;Supplement F, 198

IEC 60417 - Ref-No 5125A.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5125A-2002.svg
Function/description: To identify the switch or switch position for the function which permits rapid access within a recorded programme to repeat a section which has just been played.
Additional information:
Published in: Supplement K, 1991;Supplement J, 1990;Supplement F, 198

IEC 60417 - Ref-No 5129.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5129-1974.svg
Function/description: To identify the aerial rotation switch.
Additional information:
Published in: Supplement A, 1974

IEC 60417 - Ref-No 5134.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5134-1985.svg
Function/description: On packages containing electrostatic-sensitive devices and on the devices themselves.
Additional information:
For further information see IEC 60747-1.

IEC 60417 - Ref-No 5140.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5140-1993.svg
Function/description: To indicate elevated, potentially dangerous, levels of non-ionizing radiation.
Additional information:
In case of application in a warning sign the rules according to ISO 3864 shall be adhered to.

IEC 60417 - Ref-No 5141.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5141-1974.svg
Function/description: To identify the minimum position of the anti sea-clutter control.
Additional information:
* See also symbol 5161 * Published in: Supplement A, 1974

IEC 60417 - Ref-No 5142.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5142-1974.svg
Function/description: To indicate the minimum position of the anti rain-clutter control.
Additional information:
* See also symbol 5162 * Published in: Supplement A, 1974

IEC 60417 - Ref-No 5156.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5156-03.svg
Function/description: To identify switches, controls, connectors or terminals which connect electrical equipment to the mains through a transformer. It can also be used on an envelope or a case to indicate that it contains a transformer (e.g. in the case of a plug-in device).
Additional information:
1. The symbol may be used without the vertical bars to indicate ""separating transformer"" defined in IEC 61558-1.;2. To indicate a fail-safe function, the letter F may be used adjacent of the symbol.
  • IEC 60417 - Ref-No 5156-1977.svg
Function/description: To identify switches, controls, connectors or terminals which connect electrical equipment to the mains through a transformer. It can also be used on an envelope or a case to indicate that it contains a transformer (e.g. in the case of a plug-in device).
Additional information:
Published in: Supplement C, 1977

IEC 60417 - Ref-No 5161.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5161-1974.svg
Function/description: To indicate the maximum position of the anti sea-clutter control.
Additional information:
* See also symbol 5141 * Published in: Supplement A, 1974

IEC 60417 - Ref-No 5162.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5162-1974.svg
Function/description: To indicate the maximum position of the anti rain-clutter control.
Additional information:
* See also symbol 5142 * Published in: Supplement A, 1974

IEC 60417 - Ref-No 5172.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5172-1975.svg
Function/description: To identify equipment meeting the safety requirements specified for Class II equipment according to IEC 60536.
Additional information:
* The position of the double-square symbol shall be such that it is obvious that the symbol is part of the technical information and can in no way be confused with the manufacturer's name or other identifications * Published in: Supplement B, 1975

IEC 60417 - Ref-No 5180.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5180-1991.svg
Function/description: To identify equipment meeting the safety requirements specified for class III according to IEC 60536.
Additional information:
Published in: Supplement K, 1991

IEC 60417 - Ref-No 5183.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5183-2002.svg
Function/description: To identify the control element by means of which a quantity, for instance speed, heating power, freezing temperature, depression, can be changed. The maximum value of this quantity can be temporarily switched on by an additional operation.
Additional information:
* Only the linear version is given since the radius of the base of the curved version depends on the diameter of the control concerned. The curved version is shown in ISO 7000-1364. * See also symbols 5004 and 5181 * Note (2) was improved on 2008-01-07 * Published in: Supplement O, 1996;3C/295/DIS

IEC 60417 - Ref-No 5196.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5196-1978.svg
Function/description: To identify a gyro indicator.
Additional information:
Published in: Supplement D, 1978

IEC 60417 - Ref-No 5197.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5197-1978.svg
Function/description: To identify the control which sets a gyro indicator.
Additional information:
Published in: Supplement D, 1978

IEC 60417 - Ref-No 5204.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5204-1978.svg
Function/description: To identify the sense-aerial (sense-antenna) switch.
Additional information:
Published in: Supplement D, 1978

IEC 60417 - Ref-No 5219.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5219-1993.svg
Function/description: On an electric toy, to indicate that the toy has to be supplied from a safety isolating transformer.
Additional information:
* Replaced by IEC 60417-C00066 * Published in: Supplement L, 1993

IEC 60417 - Ref-No 5221.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5221-1990.svg
Function/description: To identify a transformer of the isolating type.
Additional information:
Published in: Supplement J, 1990

IEC 60417 - Ref-No 5222.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5222-1990.svg
Function/description: To identify a safety isolating transformer.
Additional information:
Published in: Supplement J, 1990

IEC 60417 - Ref-No 5252.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5252-1993.svg
Function/description: To identify the control causing a call to be set aside for a limited period.
Additional information:
Published in: Supplement L, 1993

IEC 60417 - Ref-No 5310.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5310-1985.svg
Function/description: To indicate the use of pulses assembled in a frame.
Additional information:
Published in: Supplement G, 1985

IEC 60417 - Ref-No 5311.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5311-1985.svg
Function/description: To indicate the use of pulses assembled in a multiframe.
Additional information:
Published in: Supplement G, 1985

IEC 60417 - Ref-No 5312.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5312-1985.svg
Function/description: To indicate frame alignment.
Additional information:
Published in: Supplement G, 1985

IEC 60417 - Ref-No 5313.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5313-1985.svg
Function/description: To indicate that frame alignment has been lost.
Additional information:
Published in: Supplement G, 1985

IEC 60417 - Ref-No 5314.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5314-1985.svg
Function/description: To indicate an error in the frame alignment signal.
Additional information:
Published in: Supplement G, 1985

IEC 60417 - Ref-No 5315.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5315-1985.svg
Function/description: To indicate a two-level signal, for example a binary signal.
Additional information:
Published in: Supplement G, 1985

IEC 60417 - Ref-No 5316.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5316-1985.svg
Function/description: To indicate a three-level signal, for example a bipolar signal.
Additional information:
Published in: Supplement G, 1985

IEC 60417 - Ref-No 5317.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5317-1985.svg
Function/description: To indicate a binary coded signal, for example in pulse code modulation (PCM).
Additional information:
Published in: Supplement G, 1985

IEC 60417 - Ref-No 5319.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5319-1990.svg
Function/description: To identify the alarm inhibit on control equipment.
Additional information:
* The type of alarm may be indicated inside the triangle or below the triangle * Published in: Sumpplement J, 1990

IEC 60417 - Ref-No 5390.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5390Rev.svg
Function/description: To indicate a reference to a normal patient, or to indicate a person and human body.
Additional information:
* [Associated with IEC 60417-5389, this symbol applies to the more obese patient. Associated with IEC 60417-5391, this symbol applies to the thinner patient. ] * Published in: Supplement G, 1985
  • IEC 60417 - Ref-No 5390Rev2.svg
Function/description: [To indicate a reference to a person or human body. On medical equipment this graphical symbol is used to indicate a reference to a normal patient.]
Additional information:
* [In combination with IEC 60417-5389, this symbol applies to the more obese patient. In combination with IEC 60417-5391, this symbol applies to the thinner patient.] * Published in: Supplement G, 1985
  • IEC 60417 - Ref-No 5390(2002-10-07).svg
Function/description: To indicate a reference to a normal patient.
Additional information:
* Associated with symbol 5389, this symbol applies to the more obese patient. ;Associated with symbol 5391, this symbol applies to the thinner patient. * Published in: Supplement G, 1985

IEC 60417 - Ref-No 5411.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5411-1985.svg
Function/description: To indicate a reference to a black-to-white image reversal.
Additional information:
Published in: Supplement G, 1985

IEC 60417 - Ref-No 5412.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5412-1985.svg
Function/description: To indicate everything concerning the reference field.
Additional information:
Published in: Supplement G, 1985

IEC 60417 - Ref-No 5416.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5416Rev.svg
Function/description: [To identify a display, or the control for the display, of the remaining time until the end of an operation (such as cooking, washing, recording, etc.). On biometric systems, to indicate the need for more time to process.]
Additional information:
See also IEC 60417-5415.
  • IEC 60417 - Ref-No 5416(2002-10-07).svg
Function/description: To identify a display, or the control for the display, of the remaining time until the end of an operation (such as cooking, washing, recording, etc.).
Additional information:
* See also symbol 5415. * Published in: Amendment 1, 2000;3C/401/FDIS;3C/351/CDV;3C/334/CD;3C/304/NP

IEC 60417 - Ref-No 5435.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5435-1994.svg
Function/description: To identify a combined control for brightness and contrast.
Additional information:
Published in: Supplement M, 1994

IEC 60417 - Ref-No 5467.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5467-1994.svg
Function/description: To identify the control by which the displayed picture can be frozen.
Additional information:
* The triangles may be filled in * Published in: Supplement M, 1994

IEC 60417 - Ref-No 5477.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5477B.svg
Function/description: Alternative graphical representation. Same meaning as 5477A.
Additional information:
Title and meaning (description) were changed to be aligned with IEC 60417-5477A by the Change Request IEC 60417-C00074 on 2008-03-14.
  • IEC 60417 - Ref-No 5477-1994.svg
Function/description: To identify the control to cancel the displayed picture.
Additional information:
Published in: Supplement M, 1994

IEC 60417 - Ref-No 5483.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5483-1994.svg
Function/description: In teletext mode, to identify the control to decrement the selected page number by one.
Additional information:
Published in: Supplement M, 1994

IEC 60417 - Ref-No 5484.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5484-1994.svg
Function/description: In teletext mode, to identify the control to increment the selected page number by one.
Additional information:
* The triangle may be filled in * Published in: Supplement M, 1994

IEC 60417 - Ref-No 5513.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5513-1994.svg
Function/description: To identify the control by which the picture-in-picture (PIP) can be moved, for instance clockwise.
Additional information:
Published in: Supplement M, 1994

IEC 60417 - Ref-No 5514.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5514-1994.svg
Function/description: To identify the control by which the picture-in-picture (PIP) can be frozen.
Additional information:
* PIP = Picture-in-Picture * Published in: Supplement M, 1994

IEC 60417 - Ref-No 5515.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5515-1994.svg
Function/description: To identify the control by which the picture-in-picture (PIP) and the main picture can be exchanged.
Additional information:
Published in: Supplement M, 1994

IEC 60417 - Ref-No 5516.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5516-1994.svg
Function/description: To identify the control by which a source for a picture-in-picture (PIP) can be selected.
Additional information:
* The triangle may be filled in * Published in: Supplement M, 1994

IEC 60417 - Ref-No 5520.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5520-1994.svg
Function/description: In teletext mode, to identify the subtitle mode.
Additional information:
Published in: Supplement M, 1994

IEC 60417 - Ref-No 5546.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5546-1994.svg
Function/description: To identify a control to check the condition of a (primary or secondary) battery or to identify the battery condition indicator.
Additional information:
According to the condition of the battery, the size of the darkened area may vary.

IEC 60417 - Ref-No 5550.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5550-1994.svg
Function/description: To identify the control to raise the tone arm.
Additional information:
Published in: Supplement M, 1994

IEC 60417 - Ref-No 5551.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5551-1994.svg
Function/description: To identify the control to lower the tone arm.
Additional information:
* In order to avoid confusion with ISO 7000-0542, the symbol shall be oriented as shown * Published in: Supplement M, 1994

IEC 60417 - Ref-No 5569.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5569-1995.svg
Function/description: To identify on a control that a function is locked or to show the locked status.
Additional information:
Published in: Supplement N, 1995;3C(Central Office)192

IEC 60417 - Ref-No 5605.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5605-1995.svg
Function/description: To identify the control or the operating condition for the setting of the nozzle which is suited for a smooth floor or surface.
Additional information:
Published in: Supplement N, 1995;3C(Central Office)191

IEC 60417 - Ref-No 5606.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5606-1995.svg
Function/description: To identify the control or the operating condition for the setting of the nozzle which is suited for carpets.
Additional information:
Published in: Supplement N, 1995;3C(Central Office)191

IEC 60417 - Ref-No 5631.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5631-2002.svg
Function/description: To distinguish the controls and terminals for a three component video signal from those for other video signals.
Additional information:
Published in: Supplement O, 1996;3C/293/DIS

IEC 60417 - Ref-No 5725.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5725-2002.svg
Function/description: To indicate a reference to a shockwave head.
Additional information:
Published in: Amendment 1, 2000;3C/422/FDIS;62A/231/CDV

IEC 60417 - Ref-No 5726.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5726-2002.svg
Function/description: To identify the control or the indicator for the selection of or positioning of the shockwave head in overtable position.
Additional information:
* The meaning of this graphical symbol depends upon its orientation. * See also symbol 5727. * Published in: Amendment 1, 2000;3C/422/FDIS;62A/231/CDV

IEC 60417 - Ref-No 5728.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5728-2002.svg
Function/description: To identify the control or the indicator to move the shockwave head along its longitudinal axis.
Additional information:
* To represent a movement in one direction only, omit the other arrow. * See also symbol 5769. * Published in: Amendment 1, 2000;3C/422/FDIS;62A/231/CDV

IEC 60417 - Ref-No 5729.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5729-2002.svg
Function/description: To identify the control or the indicator to rotate the shockwave head about an axis that is transverse to its longitudinal axis.
Additional information:
* To represent a rotation in one direction only, omit the other arrow. * Published in: Amendment 1, 2000;3C/422/FDIS;62A/231/CDV

IEC 60417 - Ref-No 5730.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5730-2002.svg
Function/description: To identify the control or the indicator to position the shockwave head into the determined target position.
Additional information:
Published in: Amendment 1, 2000;3C/422/FDIS;62A/231/CDV

IEC 60417 - Ref-No 5731.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5731-2002.svg
Function/description: To identify the control or the indicator to position the shockwave head in the park position.
Additional information:
Published in: Amendment 1, 2000;3C/422/FDIS;62A/231/CDV

IEC 60417 - Ref-No 5732.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5732-2002.svg
Function/description: To identify the control or the indicator to decouple the shockwave head from the patient.
Additional information:
* See also symbol 5733. * Published in: Amendment 1, 2000;3C/422/FDIS;62A/231/CDV

IEC 60417 - Ref-No 5733.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5733-2002.svg
Function/description: To identify the control or the indicator to couple the shockwave head to the patient.
Additional information:
* See also symbol 5732. * Published in: Amendment 1, 2000;3C/422/FDIS;62A/231/CDV

IEC 60417 - Ref-No 5734.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5734-2002.svg
Function/description: To identify the control or the indicator to position the shockwave head for therapy on the patient's left side.
Additional information:
* The shockwave head is shown in the undertable position. * The meaning of this graphical symbol depends upon its orientation. * See also symbol 5735. * Published in: Amendment 1, 2000;3C/422/FDIS;62A/231/CDV

IEC 60417 - Ref-No 5735.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5735-2002.svg
Function/description: To identify the control or the indicator to position the shockwave head for therapy on the patient's right side.
Additional information:
* The shockwave head is shown in the undertable position. * The meaning of this graphical symbol depends upon its orientation. * See also symbol 5734. * Published in: Amendment 1, 2000;3C/422/FDIS;62A/231/CDV

IEC 60417 - Ref-No 5770.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5770-2000.svg
Function/description: To indicate a reference to an alphanumeric keyboard or keypad.
Additional information:
Published in: Amendment 1, 2000;3C/402/FDIS;3C/353/CDV;3C/302/CD

IEC 60417 - Ref-No 5773.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5773-2000.svg
Function/description: To indicate a reference to the image display in interlaced mode.
Additional information:
Published in: Amendment 1, 2000;3C/402/FDIS;3C/353/CDV;3C/302/CD

IEC 60417 - Ref-No 5785.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5785Rev.svg
Function/description: [To identify equipment which is suitable for the use in the tropics.For new applications, the use of this symbol is deprecated and IEC 60417-6332 shall be used.]
Additional information:
* Equipment is suited for use in the tropics in accordance with ISO 5155 if the required storage temperature is maintained at an ambient temperature between +18º C and +43º C * [ISO 5155 was withdrawn and replaced by ISO 15502 and this was replaced by IEC 62552 and this in turn has been replaced by the IEC 62552 series. None of these standards nor IEC 60335-2-24 use symbols IEC 60417-5785 (2002-10-07) or IEC 60417-5786 (2002-10-07). They use a letter to indicate the climate class.] * Published in: Amendment 2, 2002;3C/620/FDIS;3C/519/CDV;3C/427/CD;3C/354/CD
  • IEC 60417 - Ref-No 5785(2002-10-07).svg
Function/description: To identify equipment which is suitable for the use in the tropics.
Additional information:
* Equipment is suited for use in the tropics in accordance with ISO 5155 if the required storage temperature is maintained at an ambient temperature between +18º C and +43º C * Published in: Amendment 2, 2002;3C/620/FDIS;3C/519/CDV;3C/427/CD;3C/354/CD

IEC 60417 - Ref-No 5786.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5786Rev.svg
Function/description: [To identify equipment which is suitable for the use in the subtropics.For new applications, the use of this symbol is deprecated and IEC 60417-6332 shall be used.]
Additional information:
* Equipment is suited for use in the subtropics in accordance with ISO 5155 if the required storage temperature is maintained at an ambient temperature between +18º C and +38º C * [ISO 5155 was withdrawn and replaced by ISO 15502 and this was replaced by IEC 62552 and this in turn has been replaced by the IEC 62552 series. None of these standards nor IEC 60335-2-24 use symbols IEC 60417-5785 (2002-10-07) or IEC 60417-5786 (2002-10-07). They use a letter to indicate the climate class.] * Published in: Amendment 2, 2002;3C/620/FDIS;3C/519/CDV;3C/427/CD;3C/354/CD
  • IEC 60417 - Ref-No 5786(2002-10-07).svg
Function/description: To identify equipment which is suitable for the use in the subtropics.
Additional information:
* Equipment is suited for use in the subtropics in accordance with ISO 5155 if the required storage temperature is maintained at an ambient temperature between +18º C and +38º C * Published in: Amendment 2, 2002;3C/620/FDIS;3C/519/CDV;3C/427/CD;3C/354/CD

IEC 60417 - Ref-No 5855.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5855-2002.svg
Function/description: This symbol is intended only for use in premises having low-voltage supplies with current capacities equal to or greater than 100A per phase. Use of this symbol relates particularly to the conditional connection of equipment to 400/230 V public supply networks in accordance with IEC 61000-3-11, clause 4.
Additional information:
Published in: Amendment 2, 2002;3C/607/FDIS;3C/506/CDV;3C/430/CD;3C/408/INF

IEC 60417 - Ref-No 5927.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5927-2002.svg
Function/description: To identify the mode for taking a picture at the fastest shutter speed, for example, for a target moving fast.
Additional information:
Published in: IEC 60417 database;3C/904/FDIS

IEC 60417 - Ref-No 5937.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5937-2002.svg
Function/description: To indicate a reference to an active implantable cardiovascular device, for example, cardiac pacemaker or implantable cardioverter defibrillator (ICD).
Additional information:
* In case of application as a safety sign, the rules according to ISO 3864 shall be adhered to * Published in: 3C/856/FDIS

IEC 60417 - Ref-No 5986.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 5986Rev.svg
Function/description: To identify the control for a disc drive, and the single and multiple compact disc (CD) changer, or to indicate that the disc medium has been inserted, loaded or unloaded, or to indicate that the disc medium is accessed or playing.
Additional information:
This graphical symbol is also used in conjunction with a numeral to indicate a particular CD position in a multiple CD changer.
  • IEC 60417 - Ref-No 5986Rev2.svg
Function/description: To indicate the control for a disc drive, e.g. the single and multiple compact disc (CD) changer or to indicate that the disc medium has been inserted, loaded or unloaded, or to indicate that the disc medium is accessed or playing.
Additional information:
This graphical symbol is also used in conjunction with a numeral to indicate a particular position in a multiple disc changer.
  • IEC 60417 - Ref-No 5986(2006-12-22).svg
Function/description: To identify the control for a disc drive, or to indicate that the disc medium has been inserted or accessed.
Additional information:
* ISO/IEC 10646-3 1F4BF OPTICAL DISC * Published in: 3C/1495/FDIS, 3C/1507/RVD

IEC 60417 - Ref-No 6012.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 6012-2008.svg
Function/description: To identify an isolating transformer intended to limit the influence of the input voltage variations.
Additional information:
* To indicate a fail-safe function, the letter F may be used adjacent of the graphical symbol. * To identify the isolating transformer of the type of constant voltage non-short-circuit proof, the symbol element 5221 shall be replaced by symbol 5944 without the vertical bars. * To identify the isolating transformer if the type of constant voltage short-circuit proof, the symbol element 5221 shall be replaced by symbol 5945.

IEC 60417 - Ref-No 6181.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 6181(2013).svg
Function/description: To indicate that a specific separate supply unit is required for connecting electrical equipment to the supply mains.[]In an application of this symbol, the width shall be at least 12 mm.
Additional information:
* IEC 60335-2-76 provides further technical specifications. * See aslo IEC 60417-5926: Polarity of d.c. power connector.;It may have wider application.

IEC 60417 - Ref-No 6408.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 6408Rev.svg
Function/description: To indicate that the structure of the coupling system is capacitive.
Additional information:
* See also IEC 60417-6409. * For technical detail including the location of the graphical symbol, see IEC 62271-213.
  • IEC 60417 - Ref-No 6408(2018-04).svg
Function/description: To identify the capacitive indicating element and front accessible socket outlet of the device used to detect and indicate the presence or absence of operating voltage and to deliver a signal for other functions, for example, phase comparison, voltage measurement.
Additional information:
* See also IEC 60417-6409. * For technical details, see IEC 62271-213.

IEC 60417 - Ref-No 6409.svg[Quelltext bearbeiten]

  • IEC 60417 - Ref-No 6409Rev.svg
Function/description: To indicate that the structure of the coupling system is resistive.
Additional information:
* See also IEC 60417-6408. * For technical detail including the location of the graphical symbol, see IEC 62271-213.
  • IEC 60417 - Ref-No 6409(2018-04).svg
Function/description: To identify the resistive indicating element and front accessible socket outlet of the device used to detect and indicate the presence or absence of operating voltage and to deliver a signal for other functions, for example, phase comparison, voltage measurement.;Notes:
Additional information:
* See also IEC 60417-6408. * For technical details, see IEC 62271-213.